Operation
Status Parameters
Status parameters give the operating status of the HydroRanger 200. You can access
parameters with the hand programmer (see page 26) or with Dolphin Plus (see page 22).
Remote SCADA system access is also possible.
Controlling the Display
RUN mode provides numerous parameters and variables that you can track on the
display (see Display on page 17).
The LCD displays EEEE if a value is too long.
Adjusting the primary reading for four-digit LCD readout:
Parameter Values
P203 mA Output Value 0 to 22 – Current mA output
P254 Scaled mA Input Value 0 to 9999 – Current mA input after scaling
P275 Scaled Discrete Input Value Shows current value of discrete input,
values vary by DI function
P322 LCD Total Low The last four digits of the totalizer
P323 LCD Total High The first four digits of the totalizer
P341 Run Time The number of days the HydroRanger 200
has been operating
P342 Start Ups The number of times power has been
cycled
P664 Temperature Current temperature measured by
transducer
P707 Rate Value Current rate of material level change
P708 Volume Rate Display Current rate of material volume change
P729 Scan Time Seconds since last level scan
P806 Echo Strength Strength of primary echo
P920 Reading Measurement Current primary reading
P921 Material Measurement Current level from P007–Span
P922 Space Measurement Empty space above the material level
P924 Volume Measurement Current volume value, if programmed
P925 Flow Measurement (OCM) Current flow value, if OCM programmed
P926 Head Measurement (OCM) Current level, if OCM programmed
P927 Distance Measurement Distance from transducer face to material
Parameter Action
P060 Decimal Position Sets maximum number of decimals
P061 Convert Reading Scales the reading to fit
P062 Offset Reading Shifts the reading up or down by a fixed amount