Commissioning (software)
2.7 Commissioning modes
Control Units CU240S
2-52 Operating Instructions (Compact), 04/2006, A5E00766042B AA
2.7.10 Reset parameters to factory settings
Overview
With a factory setting a defined initial state of all of the inverter parameters can be realized.
You can re-establish the initial state by carrying-out a factory via p0970. The factory setting
values are designated as "Def" in the parameter list.
After a factory reset, the inverters have the following basic settings:
CUs with RS485 interface (no PROFIBUS interface)
• Control using the digital inputs
– ON/OFF using DI0
– Direction of rotation reversal using DI1
– Fault acknowledgement using DI2.
• Setpoint input using analog input 1
• Signal output using the digital outputs
– Fault active using DO0
– Warning active using DO1.
• Actual frequency using the analog output
• The basic V/f characteristic is the control mode (P1300 = 0)
• Asynchronous motor (P0300 = 1).
CUs with PROFIBUS interface
• For the PROFIBUS variants the command source and setpoint source will be set to
PROFIBUS communication.
• The basic V/f characteristic is the control mode (P1300 = 0)
• Asynchronous motor (P0300 = 1).
Note
When resetting the parameters to the factory setting, the communications memory is re-
initialized. This means that communications are interrupted for the time it takes to perform
the reset.