Siemens HF 35M 562 B Specifications Page 55

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 54
Installation
SIMATIC - ET 200pro motor starters
GWA 4NEB 950 5661-02 DS 06
3-11
3.9 Removing the motor starters
A motor starter can be removed from the rear wall bus module during operation.
The feeder must be de-energized, e.g. repair switch switched off. Remove
the cable to the motor and both energy jumper plugs on the left and right from
the motor starter to be replaced. Press the relevant locking lever on the plugs
downwards. Unfasten the 3 Phillips bolts as shown in the figure below and
remove the motor starter from the rear wall bus module.
Caution
If you remove more than one module from the ET 200pro, the station switches
to STOP.
The table below describes how to remove motor starters using the example
of a direct starter.
Drawing Procedure / description
1 Ensure that the 400 V supply
is shut off (e.g. on the repair
switch).
If required, the repair switch can
be secured against reactivation
using a padlock.
2/3
4
5/6/7
Unscrew the connections for
the M12 cables.
Unlock the plugs or covers from
X1 to X3.
Remove the plugs and covers.
Table 3-7:Removing motor starters
4
5
6
7
3
2
Page view 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 261 262

Comments to this Manuals

No comments