TC63 AT Command Set
13.24 AT^SMGO
s
TC63_ATC_V00.490 Page 357 of 501 5/24/05
Confidential / Draft - Do not copy
13.24 AT^SMGO Set or query SMS overflow presentation mode or
query SMS overflow
Syntax
Unsolicited Result Code
SMS buffer change:
^SMGO: <mode>
Status of SMS buffer has changed.
Command Description
The read command returns overflow presentation mode and SMS overflow status
The write command sets overflow presentation mode
Parameter Description
SMS overflow presentation mode
[0]
(&F)
disable
1 enable
SMS overflow status
0 space available
Test Command
AT^SMGO=?
Response(s)
^SMGO: (list of supported<n>s)
OK
Read Command
AT^SMGO?
Response(s)
^SMGO: <n>, <mode>
OK
ERROR
+CMS ERROR
Write Command
AT^SMGO=<n>
Response(s)
OK
ERROR
CME ERROR