Page view 388
TC63 AT Command Set
16.3 AT^SSTGI
s
TC63_ATC_V00.490 Page 389 of 501 5/24/05
Confidential / Draft - Do not copy
16.3 AT^SSTGI SAT Get Information
Regularly this command is used upon receipt of an URC "^SSTN" to request the parameters of the Proactive
Command.
Then the TA is expected to acknowledge the AT^SSTGI response with AT^SSTR to confirm that the Proactive
Command has been executed. AT^SSTR will also provide any user information, e.g. a selected menu item.
The Proactive Command type value specifies to which "^SSTN" the command is related.
Syntax
Parameter Description
TC63 Remote-SAT interface states
0 RESET
1 OFF
2IDLE
3 PAC
4WAIT
Related Proactive Command
Test Command
AT^SSTGI=?
Response(s)
^SSTGI:(list of supported <state>s), (list of supported <cmdType>s)
OK
Read Command
AT^SSTGI?
Response(s)
^SSTGI: <state>, <cmdType>
OK
Write Command
AT^SSTGI=<cmdType>
Response(s)
OK
ERROR
+CME ERROR
Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last
SIEMENS ! % % % % % % ! % !
<state>
(num)
<cmdType>
(num)