TC63 AT Command Set
19.6 AT^SSYNC
s
TC63_ATC_V00.490 Page 449 of 501 5/24/05
Confidential / Draft - Do not copy
Note: When the ME is in Limited Service or IDLE mode with/without PDP context activated, the on/off time ratio
of the LED is always the same, no matter whether or not power saving is enabled. The only difference is that in
SLEEP mode the duration of the on/off periods is a multiple n of the equivalent periods without SLEEP mode.
The multiple n is synchronous to the active state of CTS during SLEEP mode (where CTS is set/reset every 0.9
- 2.7 seconds. See also AT+CFUN for the timing of CTS.
n * 75 ms on / n * 3 ms off Not possible: With AT^SSYNC=1, LED
signalization is disabled in SLEEP
mode.
SLEEP mode is activated (AT+CFUN
parameter <fun> 1) while the ME is
registered to the GSM network.
n * 500 ms on / n * 25 ms
off
Not possible: With AT^SSYNC=1, LED
signalization is disabled in SLEEP
mode.
SLEEP mode is activated (AT+CFUN
parameter <fun> 1) while the ME is
registered to the GSM network. Addi-
tionally, PDP context is activated.
LED behavior ME operating status if AT^SSYNC=1 ME operating status if AT^SSYNC=2