TC63 AT Command Set
13.17 AT+CSMS
s
TC63_ATC_V00.490 Page 347 of 501 5/24/05
Confidential / Draft - Do not copy
13.17 AT+CSMS Select Message Service
Syntax
Parameter Description
0
(&F)
GSM 03.40 and GSM 03.41 (the syntax of SMS AT commands is compatible
with GSM 07.05 Phase 2 version 4.7.0; Phase 2+ features which do not require
new command syntax may be supported, e.g. correct routing of messages with
new Phase 2+ data coding schemes)
1 GSM 03.40 and GSM 03.41 (the syntax of SMS AT commands is compatible
with GSM 07.05 Phase 2+ version; the requirement of <service> setting 1 is
mentioned under corresponding command descriptions).
Mobile Terminated Messages:
0 Type not supported
1 Type supported
Mobile Originated Messages:
0 Type not supported
1 Type supported
Test Command
AT+CSMS=?
Response(s)
+CSMS: (list of supported<service>s)
OK
Read Command
AT+CSMS?
Response(s)
+CSMS: <service>, <mt>, <mo>, <bm>
OK
Write Command
AT+CSMS=<service>
Response(s)
+CSMS: <mt>, <mo>, <bm>
OK
ERROR
+CMS ERROR