TC63 AT Command Set
7.17 ATO
s
TC63_ATC_V00.490 Page 159 of 501 5/24/05
Confidential / Draft - Do not copy
7.17 ATO Switch from command mode to data mode / PPP online
mode
Syntax
Command Description
ATO is the corresponding command to the +++ escape sequence: When you have established a CSD call or a
GPRS connection and TA is in command mode, ATO causes the TA to resume the data or GPRS connection and
takes you back to data mode or PPP online mode.
Parameter Description
[0] Switch from command mode to data mode
Exec Command
ATO[<n>]
Response(s)
If connection is not successfully resumed:
NO CARRIER
or
TA returns to data mode from command mode
CONNECT <text>
Note: <text> output only if ATX parameter setting with value > 0.
Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last
V.250 ! % § % % ! ! ! ! !
<n>
(num)