Siemens TC63 User Manual Page 112

  • Download
  • Add to my manuals
  • Print
  • Page
    / 501
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 111
TC63 AT Command Set
5.2 AT+CPIN2
s
TC63_ATC_V00.490 Page 112 of 501 5/24/05
Confidential / Draft - Do not copy
5.2 AT+CPIN2 PIN2 Authentication
AT+CPIN2 controls network authentication of the TC63.
The read command returns an alphanumeric string indicating whether or not network authentication is required.
The write command allows the TC63 to store the entered password. This may be for example the SIM PIN2 to
benefit from the features listed below, or the SIM PUK2 to replace a disabled PIN2 with a new one. Note that
PIN2 can only be entered if PIN1 authentication was done.
If the TC63 is requesting SIM PUK2, use <pin> to enter the PUK2, followed by <new pin> to specify the new
PIN2.
Syntax
Parameter Description
Password (string type), usually SIM PIN2 or, if requested, SIM PUK2.
If the requested code was SIM PUK2: new password (PIN2).
See Section 5.1.1, What to do if PIN or password authentication fails? for more information about when you may
need to enter the PUK.
READY ME is not pending for any password.
SIM PIN2 ME is waiting for SIM PIN2.
This <code> is returned only when PIN2 authentication has not yet been done
or has failed ("+CME ERROR:17").
SIM PUK2 ME is waiting for SIM PUK2.
This <code> is returned only when PIN2 authentication has failed and ME is
pending for SIM PUK2 (i.e. "+CME ERROR:18").
Test Command
AT+CPIN2=?
Response(s)
OK
Read Command
AT+CPIN2?
Response(s)
+CPIN2: <code>
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CPIN2=<pin>[, <new pin>]
Response(s)
OK
ERROR
+CME ERROR: <err>
Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last
GSM 07.07 % % % % % % % ! % !
<pin>
(str)
<new pin>
(str)
<code>
(text)
Page view 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 500 501