Page view 270
Technical data
10.3 Technical data, Power Modules
Inverter with CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2011, FW 4.4, A5E02299792B AB
269
Power-dependent data, PM240 - IP20
Table 10- 1 PM240 frame size A, 3-ph. 380 V AC… 480 V, ± 10 %
Order number Without filter 6SL3224-0BE13-7UA0 6SL3224-0BE15-5UA0 6SL3224-0BE17-5UA0
Values based on Low Overload
● LO power
● LO input current
● LO output current
0.37 kW
1.6 A
1.3 A
0.55 kW
2.0 A
1.7 A
0.75 kW
2.5 A
2.2 A
Values based on High Overload
● HO power
● HO input current
● HO output current
0.37 kW
1.6 A
1.3 A
0.55 kW
2.0 A
1.7 A
0.75 kW
2.5 A
2.2 A
General values
● Power loss
● Fuse
● Cooling air requirement
● Cable cross-section for line and
motor connection
● Torque for line and motor and
motor connection
● Weight
0.097 kW
10 A
4.8 l/s
1 … 2.5 mm
2
1.1 Nm
1.2 kg
0.099 kW
10 A
4.8 l/s
1 … 2.5 mm
2
1.1 Nm
1.2 kg
0.102 kW
10 A
4.8 l/s
1 … 2.5 mm
2
1.1 Nm
1.2 kg
Table 10- 2 PM240 frame size A, 3-ph. 380 V AC… 480 V, ± 10 %
Order number Without filter 6SL3224-0BE21-1UA0 6SL3224-0BE21-5UA0
Values based on Low Overload
● LO power
● LO input current
● LO output current
1.1 kW
3.8 A
3.1 A
1.5 kW
4.8 A
4.1 A
Values based on High Overload
● HO power
● HO input current
● HO output current
1.1 kW
3.8 A
3.1 A
1.5 kW
4.8 A
4.1 A
General values
● Power loss
● Fuse
● Cooling air requirement
● Cable cross-section for line and
motor connection
● Torque for line and motor and
motor connection
● Weight
0.108 kW
10 A
4.8 l/s
1 … 2.5 mm
2
1.1 Nm
1.2 kg
0,114 kW
10 A
4.8 l/s
1 … 2.5 mm
2
1.1 Nm
1.2 kg