Commissioning
4.6 Data backup and standard commissioning
Inverter with CU240B-2 and CU240E-2 Control Units
84 Operating Instructions, 01/2011, FW 4.4, A5E02299792B AB
4.6.1.2 Transferring the setting from the memory card
If you wish to transfer the parameter setting from a memory card into the inverter
(download), you have two options:
Automatic download
The inverter power supply has been switched off.
1. Insert the memory card into the inverter.
2. Then switch-on the inverter power supply.
6,1$0,&6
6,1$0 ,&6
6,1$0,&6
6,1$0 ,&6
30
3030
&8
&8
6,1$0,&6
If there is valid parameter data on the memory card, then the inverter accepts this
automatically.
Note
Inverter with enabled safety functions
After the automatic download, the inverter also accepts all of the settings of the safety
functions.
Manual download
If you do not want to switch off the power supply, then you must
transfer the parameter setting into the inverter in the following way:
1. The inverter power supply has been switched on.
2. Insert the memory card into the inverter.
6,1$0,&6
6,1$0 ,&6
6,1$0,&6
6,1$0 ,&6
30
3030
&8
&8
6,1$0,&6
STARTER BOP-2
1. Go online with STARTER
2. In the expert list, set p0804 = 1.
3. Check the value of parameter p0804.
Once data transfer has been completed, then
p0804 = 0 is automatically set.
1. Start data transfer in the menu "EXTRAS" -
"FROM CRD".
2. Wait until the BOP-2 signals that data transfer
has been completed.