Functions
7.11 Switchover between different settings
Inverter with CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2011, FW 4.4, A5E02299792B AB
239
7.11 Switchover between different settings
In several applications, the inverter must be able to be operated with different settings.
Example:
You connect different motors to one inverter. Depending on the particular motor, the inverter
must operate with the associated motor data and the appropriate ramp-function generator.
Drive data sets (DDS)
Your can parameterize several inverter functions differently and then switch over between
the different settings.
The associated parameters are indexed (index 0, 1, 2 or 3). Using control commands select
one of the four indices and therefore one of the four saved settings.
The settings in the inverter with the same index are known as drive data set.
0
0
~
=
=
~