Siemens SINAMICS G120 Operations Instructions Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 304
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Introduction
1.5 Extended scope for adaptation
Inverter with CU240B-2 and CU240E-2 Control Units
16 Operating Instructions, 01/2011, FW 4.4, A5E02299792B AB
1.5 Extended scope for adaptation
1.5.1 BICO technology: basic principles
Principle of operation of BICO technology
Open/closed-loop control functions, communication functions as well as diagnostic and
operator functions are implemented in the inverter. Every function comprises one or several
BICO blocks that are interconnected with one another.
MOP output
speed
[rpm]
MOP enable (lower)
Inputs OutputParameter
MOP enable (higher)
p1036
r1050
p1035
MOP
Figure 1-1 Example of a BICO block: Motorized potentiometer (MOP)
Most of the BICO blocks can be parameterized. You can adapt the blocks to your application
using parameters.
You cannot change the signal interconnection within the block. However, the interconnection
between blocks can be changed by interconnecting the inputs of a block with the appropriate
outputs of another block.
The signal interconnection of the blocks is realized, contrary to electric circuitry, not using
cables, but in the software.
DI 0
ON/
OFF1
p0840
Index [0]
r0722.0
Figure 1-2 Example: Signal interconnection of two BICO blocks for digital input 0
Binectors and connectors
Connectors and binectors are used to exchange signals between the individual BICO blocks:
Connectors are used to interconnect "analog" signals. (e.g. MOP output speed)
Binectors are used to interconnect "digital" signals. (e.g. 'Enable MOP up' command)
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 303 304

Comments to this Manuals

No comments