Siemens Schweiz AG Basic units RVS61.843 and RVS41.813 CE1U2355en_02
Landis & Staefa Division The settings in detail 3. Juli 2008
A
cknow
ledgm.
Function error
repetition
No.: Error text
Locati
on
Error
priority
Manuall
y
A
ctive
1st status
mess.
HP
operation
Responsibility
no.
207: Fault cooling circuit
LPB --- --- --- --- ---
1 (installer)
208: Flow supervision
LPB --- --- --- --- ---
1 (installer)
217: Sensor fault
LPB --- --- --- --- ---
1 (installer)
218: Pressure supervision
LPB --- --- --- --- ---
1 (installer)
Number* These plant states do not directly lead to an error message, but first
deliver a status message upon initial startup.
An error message is delivered only if the same fault occurs the number of
times set for an adjustable period of time.
The LPB system displays the following error messages only as common faults:
ackno
wledg
ment
Function error repetition
No.: Error text
Locati
on
error:
-
priorit
y
Manua
lly
A
ctive
1. 1st status
message
Heat pump
operation
Responsibility
no.
207: Fault cooling circuit
LPB --- --- --- --- ---
1 (installer)
208: Flow supervision
LPB --- --- --- --- ---
1 (installer)
217: Sensor fault
LPB --- --- --- --- ---
1 (installer)
218: Pressure supervision
LPB --- --- --- --- ---
1 (installer)
6.22 Service / special operation
Maintenance functions
Maintenance functions can be used as a preventive measure for periodic monitoring of
plant. All maintenance functions can be individually activatd and deactivated.
The controller delivers maintenance messages automatically if the settings made for
the maintenance functions are violated, either upward or downward.
Line no. Operating line
7070 HP interval
7071 HP time since maint
7072 Max starts compr1/hrs run
7073 Cur starts compr1/hrs run
7074 Max starts compr2/hrs run
7075 Curr starts comp2/hrs run
7076 Diff condens max/week
7077 Cur diff condens max/week
7078 Diff condens min/week
7079 Cur diff condens min/week
7080 Diff evap max/week
7081 Cur diff evap max/week
7082 Diff evap min/week
7083 Cur diff evap min/week
7090 DHW storage tank interval
7091 DHW stor tank since maint
7092 DHW charg temp HP min
7093 Curr DHW charg temp HP
Interval for heat pump maintenance
Setting of interval (in months) at which the heat pump requires service.
Display of period of time (in months) elapsed since last service visit.
HP interval
HP time since maint
Only RVS61..