11 Alarms 11.90
11.11 Alarm list ACKNOWLEDGE
Explanation:
Remedy:
A variable has been selected which cannot be represented in control.
Check display using programming workstation; re-input variable if
necessary
3046
Variable error
Explanation:
Remedy:
3048
Wrong workpiece definition
Minimum and maximum values have been reversed when defining the
workpiece.
Example: Xmin. = 100
Xmax. = 50
Check workpiece definition for valid values.
Explanation:
Remedy:
No values or incorrect values have been input when defining the
simulation area.
• Check values for simulation area (all levels).
• Simulation may only be restarted after depressing
RESET and the ACKNOWLEDGE ALARM key.
3049
Wrong simulation area
Explanation: Simulation data incorrect/not defined.
3050
Incorrect input
Explanation:
Remedy:
3063
Data block not available
In PLC STATUS a DB No. was selected, which is not available.
Select or create correct DB.
11–46 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02
SINUMERIK 810 GA3/820 GA3 (IA)