11 Alarms 09.91
11.11 Alarm list ACKNOWLEDGE
Explanation:
Remedy:
3028
Too many fields / variables
Configuring error in selected display. The number of fields or
variables is limited in view of the specific length of the transfer
buffer. A maximum number of fields/variables cannot be stated
since the fields/variables can have different formats and positions.
Check display with programming workstation
Reduce number of fields/variables
Split contents over 2 displays if necessary
Explanation:
Remedy:
3029
Graphics option not available
Graphics elements have been configured in the selected display
although NC MD 5015 bit 2 ”Graphics” is not available in the control.
Set bit 2 of NC MD 5015
Configure displays without graphics elements
Explanation:
Remedy:
Note:
3030
Cursor memory not available
The cursor memory configured in the selected display is not correct
(number not permitted or too large).
Re-determine cursor memory with programming workstation.
The function of the cursor memory is to place the cursor
at its original position when the display is called
once more.
Note:
3032
Too many fields / variables (DIS GGS)
As for Alarm 3028
Explanation:
Remedy:
3033
Display text not available
An error has occurred during linking with the programming workstation.
Check link list and re-link with programming workstation
(watch for link errors!).