09.91 11 Alarms
11.9 General RESET alarms
11.9 General RESET alarms
Effect:
Explanation:
2032
Stop during threading
• Setpoint 0
• NC Start disabled
• Stoppage has occurred in feedrate per revolution during thread
cutting, resulting in destruction of the thread.
• Axis-specific feed enable was cancelled during ”G33 active”
Cause:
2030
Wrong path increment
• Set part position too large with spline.
Incorrect spline coefficient K, path line I or axis position
• Axis offset not carried out before spline selection
Scan:
Effect:
Remedy:
2031
Eval. factor too high/low MD 388*
On every axis movement
• NC START disabled
• Setpoint 0
• Stop in processing
Check MD 388*
Scan:
Effect:
Significance:
Remedy:
Caution:
2000
Emergency stop
Cyclically
• NC START disabled
• Setpoint 0
• Servo enable cancelled after time in MD 156 has expired
• Follow-up mode
PLC outputs ”EMERGENCY STOP” signal to NC.
• Check with PLC-STATUS whether Q 78.1 = 0
• Check whether EMERGENCY STOP cam approached or
EMERGENCY STOP pushbutton actuated
• Check PLC program
According to legal requirements the EMERGENCY STOP status
must be selected not only by the control (software) but also
by the hardware (using relays).
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–23
SINUMERIK 810 GA3/820 GA3 (IA)