09.91 11 Alarms
11.9 General RESET alarms
11.9 General RESET alarms
Effect:
Explanation:
2032
Stop during threading
Setpoint 0
NC Start disabled
Stoppage has occurred in feedrate per revolution during thread
cutting, resulting in destruction of the thread.
Axis-specific feed enable was cancelled during ”G33 active”
Cause:
2030
Wrong path increment
Set part position too large with spline.
Incorrect spline coefficient K, path line I or axis position
Axis offset not carried out before spline selection
Scan:
Effect:
Remedy:
2031
Eval. factor too high/low MD 388*
On every axis movement
NC START disabled
Setpoint 0
Stop in processing
Check MD 388*
Scan:
Effect:
Significance:
Remedy:
Caution:
2000
Emergency stop
Cyclically
NC START disabled
Setpoint 0
Servo enable cancelled after time in MD 156 has expired
Follow-up mode
PLC outputs ”EMERGENCY STOP” signal to NC.
Check with PLC-STATUS whether Q 78.1 = 0
Check whether EMERGENCY STOP cam approached or
EMERGENCY STOP pushbutton actuated
Check PLC program
According to legal requirements the EMERGENCY STOP status
must be selected not only by the control (software) but also
by the hardware (using relays).