11 Alarms 09.91
11.11 Alarm list ACKNOWLEDGE
11.11 Alarm list ACKNOWLEDGE
Explanation:
Remedy:
3000
General program error
A general programming error which cannot be precisely defined
has been made in a block in the program.
Example: • The programmed axis is not available at the machine.
• Incorrect interpolation parameters programmed.
• Axis duplication option active and D number in part
program greater than 49.
• Spindle was programmed in rotary axis mode.
Check defective block in ”Correction Block”
Cursor is set in front of incorrect word if possible.
Number of the defective block is behind the alarm no. in the alarm line.
Explanation:
Remedy:
3001
Geometry parameters >5
More than 5 geometry parameters such as axes, interpolation
parameters, radii, angles etc. have been programmed in the block.
As for Alarm 3000
Explanation:
Remedy:
3002
Polar/radius error
No programming in block with polar/radius programming for:
• Angle
• Radius
• Centre point coordinates
As for Alarm 3000
Explanation:
Remedy:
3003
Invalid address
• The address programmed is not defined in the
machine data.
• The axis names for basic setting plane (MD 548*, 550*,
552*) do not correspond to the defined axis designations
(MD 568*)
• Axis duplication option active and tool system 2 axes programmed
in part program.
MD 108*...MD 118* are not correctly assigned
The MDs for I, J, K parameters (MD 304*) contain a number not equal
to 0, 1, 2 or 3.
• As for Alarm 3000
• Correct machine data
11–38 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02