11.90 11 Alarms
11.11 Alarm list ACKNOWLEDGE
Explanation:
Remedy:
3011
Number of axes > 2 / axes twice
• An axis has been programmed twice in the same block.
• More axes have been programmed than are available at the machine
As for Alarm 3000
Explanation:
Remedy:
3012
Block not in memory
• Program not terminated with M02 / M30 / M17.
• Block number stated in the jump (@ 100, 11x, 12x, 13x) was not
found in the specified direction.
As for Alarm 3000
Explanation:
Remedy:
3013
Simulation disabled
With the machine data set accordingly, graphic simulation (for checking
the part program) is only possible if no program is being processed
simultaneously at the machine (depending on MD 5007,
bit 4).
• Interrupt the part program at a suitable point using the
RESET key
• Process the part program up to the end, then simulate
Effect:
Explanation:
Remedy:
3016
External data input error
Data transfer interrupted.
With external data input from the PLC to the NC:
• Code is incorrect
• Value excessive
• Dimensional identifier impermissible
• Option not available
• Check PLC program
• Check NC MD, PLC MD
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–41