01.93 11 Alarms
11.7 RS 232 C (V.24) Alarms
POWER ON alarms
Cause:
Effect:
Remedy:
40
Wrong data in MD 576*
Wrong data in MD 576* bit 7, 6, 5
NC START disabled
Activate option or check MD 576*
Cause:
Explanation:
41
Error absolute submodule
Error when using a SIPOS absolute submodule
The type of error can be seen from the line ”Status absolute sub-
module” in the ”Service data axis” display.
The error number is displayed. The significance of the error number
can be seen from the documentation on the SIPOS absolute encoder
submodule.
Scan:
Effect:
Explanation:
Remedy:
48
PLC alarm texts from UMS not allowed
With POWER ON
UMS declared invalid
If the PLC alarm texts are not read in from tape (NC MD 5012 bit 7) but
instead are configured using the WS800 programming workstation, the
texts are transferred to the UMS together with cycles, displays and
menus. On checking the inventory of the UMS, the control has
established the presence of both PLC alarm texts
from tape and alarm texts in the UMS.
Reset NC MD 5012 bit 7
Check UMS and re-configure if necessary using WS800
87
Illegal software limit switch
Cause:
Effect:
Comment:
An illegal value has been entered in the machine data for software limit
switch MD 224*, 228*, 232*, 236*) or prelimit switch (MD 376*).
Removal of NC-READY2
Locking of NC START
The check is performed effectively after POWER ON, independently of
NC MD 560* bit 5 ”Working area limitation, Software limit switch”.
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–17
SINUMERIK 810 GA3/820 GA3 (IA)