11.90 11 Alarms
11.9 General RESET alarm
Scan:
Effect:
Explanation:
Remedy:
Note:
2153
Control loop spindle - HW
Cyclically
• NC START disabled
Setpoint 0
• NC Ready 2 cancelled
• Spindle servo enable cancelled after time in MD 4470
has expired
As for Alarm 132*
As for Alarm 132*
Axis measuring-circuit alarms which occur after the alarm in the order
control loop - spindle - hardware are recognized but not displayed.
Cyclically
In measuring systems with a contamination signal, the measuring
system has signalled an error to the NC.
NC START disabled
Check measuring system
Spindle meas. system dirty
2154
Scan:
Explanation:
Effect:
Remedy:
Scan:
Effect:
Explanation:
Remedy:
2155
Option M19 not available
• During processing in AUTOMATIC/MDI mode
NC START disabled
”M19 S...” programmed in part program although this function
is not available.
• Correct program
• Retrofit option ”M19”
Machining halted
Range of values from 0. 000 01 to 99, 999 99 exceeded
Check NC program block with G51 P..
Effect:
Significance:
Remedy:
2160
Scale factor not allowed
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–33