11.90 11 Alarms
11.9 General RESET alarm
Scan:
Effect:
Explanation:
Remedy:
Note:
2153
Control loop spindle - HW
Cyclically
NC START disabled
Setpoint 0
NC Ready 2 cancelled
Spindle servo enable cancelled after time in MD 4470
has expired
As for Alarm 132*
As for Alarm 132*
Axis measuring-circuit alarms which occur after the alarm in the order
control loop - spindle - hardware are recognized but not displayed.
Cyclically
In measuring systems with a contamination signal, the measuring
system has signalled an error to the NC.
NC START disabled
Check measuring system
Spindle meas. system dirty
2154
Scan:
Explanation:
Effect:
Remedy:
Scan:
Effect:
Explanation:
Remedy:
2155
Option M19 not available
During processing in AUTOMATIC/MDI mode
NC START disabled
”M19 S...” programmed in part program although this function
is not available.
Correct program
Retrofit option ”M19”
Machining halted
Range of values from 0. 000 01 to 99, 999 99 exceeded
Check NC program block with G51 P..
Effect:
Significance:
Remedy:
2160
Scale factor not allowed
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–33