8.3.3 Local program mode direct program addresses
To access directly to the address via the Keypad buttons, without scrolling through
all the menu points you can use a shortcut by adding they following addresses
directly.
Sequence Action
P1E ZONE #1 TEXT (maximum 16 characters)
P16E ZONE #16 TEXT
P800E UPDATE EDITABLE TEXT TO ALL LCD KEYPADS
P801E RETURN ALL EDITABLE TEXT TO DEFAULT
P995E PANEL TYPE
P996E SET KEYPAD ADDRESS NUMBER FROM 1-8
P997E KEYPAD LANGUAGE
P998E AREA IDENTIFYING CHARACTER (assigning numbers or letters to
Areas)
P999E PANEL NAME DISPLAY (maximum 16 characters)
P1001E PROGRAM USER 1 NAME
P1100E PROGRAM USER 100 NAME
P2001E AREA A IDENTIFYING NAME (maximum 16 character Area name)
P2002E AREA B IDENTIFYING NAME (maximum 16 character Area name)
P3001E PROGRAM OUTPUT 1 NAME
P3008E PROGRAM OUTPUT 8 NAME
Tab. 3 Shortcut programming codes Local program mode
8.3.4 Exiting local edit program mode
Press and hold the
C
tr
l
button for 2 seconds and the LCD keypad will leave Local
Program Mode and return to normal Mode or; press the
C
tr
l
button repeatedly until
the display reads Exit Programming, then press the
button to exit program
mode.
8.4 Programming a keypad to the system – addressing
All following programming steps in this chapter are requesting the Local Program
Mode as described before.