Programming to EN 50131
16
Building Technologies
Fire Safety & Security Products
P25E 13E Option 8:
Limit Events & Dialer to 3 of any one type
refer to chapter
14.3: Miscellaneous user options
Option 8:
Limit Events & Dialer to 3 of any one Type: if this option is turned on the panel will
not record any more than 3 events in memory for any event type during a single
arm or disarm cycle, e.g. if the AC failed 4 times while armed or disarmed the
panel will only record the AC fail 3 times in memory and will only report the AC fail
3 times to the dialer. As soon as the arm state has changed any count are reset
back to zero again. If this option is off there is no limit on the recording and
reporting of events.
According EN 50131-3 the events of the same type should be limited to 3.
P36E Option 5:
Output Disabled when P25E3E timer is running
refer to chapter
16.1: Output options
Option 5:
Output Disabled when P25E 3E timer is running: this option will cause the output to
be disabled when the dialer reporting delay is active. It is designed to keep external
audible alarms silent when the dial delay is active (allowing internal alarms to warn
that the alarm will be reported to monitoring if not unset) but if the alarm hasn’t
been reset before the timer expires the external alarm will sound.
According EN 50131-3 if an alarm occurred during Exit Delay the dialer
should reported only after 30sec.
And the Siren shouldn't activate until the Exit delay is expired.
P37E Option 4:
Disable outputs during two way voice mode
refer to chapter
16.1: Output options
Option 4:
Turn Output OFF during Two Way Voice Mode: if the panel has a full duplex two
way voice board fitted and the settings at P175E 2E option 8 and P183E option 5
are set to allow full duplex mode, any outputs with this option turned on will be
disabled while two way voice is operational. This is to ensure that local sirens do
not interfere with the two way voice audio signal.
According EN 50131-3 if an alarm occurred during Exit Delay the dialer
should reported only after 30sec.
And the Siren shouldn't activate until the Exit delay is expired.
P46E Option 7:
Cannot Arm if Zone unsealed at end of Exit Delay
refer to chapter
17.1: Area arm and special function options
Option 7:
Cannot Arm if Zone unsealed at end of Exit Delay: if this option is turned on and a
zone becomes unsealed as the exit delay expires the panel will fail to arm and
report this via the dialer. The unsealed zone must be corrected and the system re-
armed again.
According EN 50131-3 the system shouldn't Arm if one of the zones is open
at the end of Exit Delay.