Voice board IAV6-90
37
Building Technologies
Fire Safety & Security Products
6.3 Operating instructions
The IAV6-90 is available in 2 versions. Both versions can be configured remotely and allow the
configuration of a phone number the system will call in the event of an alarm.
Version 9.07 additionally allows a Central Monitoring Station (CMS) to verify an alarm by listening in
after the alarm has been reported by the Control Panel.
The IAV6-90 Voice Board enables the following functionality of the Control Panel:
z Reporting using voice messages
z Alarm verification
z Remote configuration of the system
z Remote listen-in/talk-in
The two basic applications of Sintony 60 for reporting alarms are
z Reporting to a user phone
z Reporting to a CMS
The voice board supports both scenarios. It offers two modes of operation in both
scenarios, which differ mainly in the way the listen-in voice call is established:
z Holding the line open
z Auto answering
6.3.1 Alarm reporting to a user phone
6.3.1.1 Holding the line open following Domestic/Speech reporting for DTMF control
Dialer B option
P175E 2E
(Option 6 set ON)
The messages received must always be confirmed by a user by pressing #. Otherwise there may be
delays in the transmission of further alarm messages.
The dialer is set to call Domestic (Alarm tones only) or Speech (recorded
message).
After an event has occurred, the Control Panel's dialer calls the user (regular
telephone number) to report the event by sending a voice message or alarm tones
over the phone. If a kiss-off is sent (dialer acknowledge DTMF code set by the user
by parameter P175E 14E; if no kiss-off is programmed, the default DTMF is #), the
dialer will keep the telephone line open.
The user at the phone can then talk to the person at the site and listen in to the site
by using DTMF commands to turn the microphone on and off. If no kiss-off is sent
to the Control Panel by the user after having answered the call, the dialer will
repeat the call to the telephone several times (set by parameter P184E 1-8E).
Once the microphone is turned ON, the panel will keep the conversation for 1 minute. To extend the
call for a longer time, the user must press the * button before the first minute has passed. The panel
will close the microphone but not the call. If the * button is pressed once more, the panel will open the
microphone again for 1 minute.
This action can be repeated several times.
Comments to this Manuals