7ML19985CL02 SITRANS LR 300 – INSTRUCTION MANUAL Page 81
mmmmm
Parameters
P920 Reading Measurement
Displays the reading measurement that the unit is programmed for in RUN mode (P001,
operation).
P921 Material Measurement
Displays the reading measurement as though the unit were programmed to read Level
(P001 = 1).
P922 Space Measurement
Displays the reading measurement as though the unit were programmed to read Space
(P001 = 2).
P923 Distance Measurement
Displays the reading measurement as though the unit were programmed to read
Distance (P001 = 3).
P924 Volume Measurement
The calculated vessel capacity in Maximum Volume (P051) or % of Maximum Volume.
P927 Distance Measurement (0%)
The distance between the surface and the flange face.
Use P923 unless the distance information is required in percent.
Values (view only)
units showing Level/Space/Distance
Values
Range: 0.0000 to 99999
Related
Parameters
P051 Maximum Volume
Values
Range: 0.0000 to 99999 in units or % of Empty
Related
Parameters
P005 Units
P006 Empty
SITRANS LR 300.book Page 81 Monday, June 10, 2002 7:18 PM