Siemens Hicom 118 Service Manual Page 92

  • Download
  • Add to my manuals
  • Print
  • Page
    / 334
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 91
Power suppl
y
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
5-3
Installation
5.3.1 PSU1/UPS1 power supply
5.3.2 Battery for UPS1
1 battery box for wall mounting, complete with rechargeable battery and connecting cable
(0.4 m) to the power supply unit
4 wall plugs, 4 woodscrews
Bridging times, see Table 3-27
5.3.3 PSU2/UPS2 power supply
Danger
The heat sinks in the PSU are directly connected to the mains. Always unplug the
mains plug before opening the PSU housing.
Derived voltages MB and system
expansion
Function
expansion
Total
+5V DC 7W 3W 10W
-48V DC 19W 1W 20W
-45/75 V DC 4W 4W
Table 5-1 Power split PSU1/UPS1 for Hicom 108/112
Derived voltages MB and system
expansion
Function
expansion
Total
+5V DC 15W 5W 20W
–48V DC 50, 8W 2W 52, 8W
–45/75 V DC 8W 8W
Table 5-2 Power split PSU2/UPS2 for Hicom 118
!
Page view 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 333 334

Comments to this Manuals