Hicom 100 E Version 2.1, Service manual
6.5 Customer data
Extension-related data will be changed if the extension number plan for users is changed. For
this reason, the changed data must be reprogrammed following re-initialisation and
nationalisation.
6.6 Terminal test
After initial operation and nationalisation, always test each system telephone.
If the reaction to the test is not as described, the system telephone in question requires a
separate power supply (plug-in PSU).
If the date and time of day do not appear in the display after initial operation, either the system
telephone or the cabling is defective. Replace the system telephone or check the cabling.
Figure 6-1 Terminal test
6.7 Extension numbering plan, two-box system (118-2)
Enter the above password to change the extension number plan of the basic box in a two-box
system from 3-digits extension numbers (200-319) to 2-digit extension numbers (11–74).
This ensures that the extension number plan of the basic box and the expansion box is uniform.
The extension numbers in the expansion box remain 3-digit numbers and must be changed with
the ASSISTANT L PC tool.
Enter the code for
"Terminal test"
*94
All LEDs flash rapidly for approx. 5
seconds, all display characters
appear against a dark background
and a tone is audible.
Password for two-box system for
changing the extension number plan
Enter code for "System
administration".
16122320
*95