Hicom 100 E Version 2.1, Service manual
10-5
Programming guide
10.2.2 Setting a dial pause
It may be necessary to insert a pause before transmitting the dialling signal at analogue
attendant consoles (e.g. if there is a delay in the ready-to-record-digit status at the attendant
console). The pause can be defined for each route.
Example
: a 3-second pause is to be observed between line seizure and transmitting the
dialling signal to route 1 lines.
10.2.3 Changing a trunk call interval
The trunk call interval must be increased to 13 seconds for Hicom 100E if the system is
connected to analogue attendant consoles with 10-second ringing. The interval duration can
be defined for each route.
Input sequence Meaning Display
A202
Dial pause for route 1
(select route 2–4 with "+" and "–" or
directly with "#")
Route 1: no pause
B*
Change input Route 1
C
2 Pause = 3 seconds Route 1: 3 s
D<OK>
Confirm input Route 1: 3 s
E<F8>
Return to Start menu System administration
If necessary, other pause durations can be set by entering other values under point C. The
following values are possible:
0 = no pause, 1= 1 s, 2 = 3 s, 3 = 6 s, 4 = 9 s
Input sequence Meaning Display
A203
Trunk call interval for route 1
(select route 1- 4 with "+" and "–" or
directly with "#")
Route 1: 6 s
B*
Change input Route 1
C
2 Trunk call interval = 13 seconds Route 1: 13 s
D<OK>
Confirm input Route 1: 13 s
E<F8>
Return to Start menu System administration
The trunk call interval can be reset to 6 by entering "1" under point C.