Entrance telephones
Plus products
A31003-K16-X001-3-7620
,
07/99
11-4
Hicom 100 E Version 2.1, Service manual
11.3.2 Connection via door opener adapter box
Depending on the features required, the door opener may be connected via an entrance tele-
phone (door opener) adapter box (S30817-Q930-A200, with make contact).
A voice connection call to the entrance telephone can be set up from each telephone.
Door opener feature possible from each telephone.
Doorbell signalling in accordance with call allocation, see Section 6.9.1.
Figure 11-2 Door opener adapter connections
Doorbell
Door opener
Door opener
adapter box
a1
Hicom 108/112/118
from a/b motherboard or
SLA a/b
b1
Entrance telephone
2, 3 or 4-wire connection, de-
pending on the manufacturer
a2
b2
TO1
TO2
KL1
KL2
a
b
Entrance telephone
amplifier
8-16 V
~
power
supply unit
TS1
TS2
UB1
UB2
a1/b1: Connection to telephone system
a2/b2: Voice connection to entrance telephone amplifier
KL1/KL2: Doorbell connection (warning: do not apply separate-source voltage)
TO1/TO2: Connection for door opener relay
UB1/UB2: Supply voltage for door opener (8-16 V~)
TS1/TS2: Make contact for entrance telephone amplifier (if necessary*)
* More recent amplifiers feature a built-in automatic disabling device which can generally be adjusted. This