Function expansions without options bu
s
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
3-33
Overview of modules
Figure 3-22 Pin assignment of the modem adapter
Figure 3-23 Pin assignment of the printer adapter
3.7.3 Coarse protection
The modules incorporate overvoltage protectors. Additional protection can be provided by com-
mercially available connection boxes with gas-type surge arresters or the MDFU of the Hicom
125/130. National regulations must be observed. Generally speaking, the systems are not suit-
able for a cable that exits the building.
TxD2
RxD3
RTS7
CTS8
GND5
TxD2
RxD3
CTS5
RTS4
GND7
DSR6
DTR20
9-pin
SubD plug
25-pin
SubD plug
CASDT modem
S30122-K5597-X100
Suitable for:
Delrina Win FAX Pro
CPV
Spain
Aceex 1414
Elsa 2460 TL
RxD2
RTS7
GND5
RxD3
DSR6
DCD8
DTR20
GND7
9-pin
SubD plug
25-pin
SubD plug
CASDT printer
’S30122-K5597-X
Suitable for:
SIEMENS P500
EPSON LX series
Page view 67