Siemens SX Series User's Guide Page 99

  • Download
  • Add to my manuals
  • Print
  • Page
    / 453
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 98
U41272-J-Z385-3-76 99
Functions of the System Management Console Backing up/restoring the SMC
5. Insert the data cartridge containing the backed up configuration data in the DAT drive.
Check beforehand that the data cartridge is write-protected, i.e. that the write protection
tab is set at “writeable”.
6. Enter the following command to start restoring the configuration data:
SMC# /opt/FJSVscsl/bin/scslrestore -t /dev/rmt/0
7. Initiate a reconfiguration of the system components and then restart the system:
SMC# touch /reconfigure
SMC# /usr/sbin/shutdown -g0 -y -i6
The control panel LAN must be deactivated and then reactivated. To do this, use the
Machine Administration Menu (see figure 21 on page 58):
System Network Administration -> System Network Administration Configuration Tools ->
System Network Activation/Inactivation.
8. Use the device management menu of the System Console Software to restore the
monitoring log created by the device management program (this log involves data which
is automatically saved in the partition at regular intervals).
9. If necessary, check and activate the APC system (see section “Switching the server
on/off on a scheduled basis” on page 66).
10. Press the eject button of the DAT tape drive to remove the data cartridge from the drive.