Siemens SX Series User's Guide Page 364

  • Download
  • Add to my manuals
  • Print
  • Page
    / 453
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 363
364 U41272-J-Z385-3-76
X2000 channel connection error messages X2000 messages
13.5.4 HWI messages
The HWI messages are process-independent.
HWI message code:
<addr> Buffer start address for HWI opcode
<chpid> ... List of CHPIDs for the channels in question
<oc> Selected HWI opcode (four characters)
<op> Selected HWI operation (two characters)
<range> ... List of CHPID areas (x0...xF) of affected channels without further speci-
fication
...I003 write access not allowed - opcode:<oc> CHPID(s): <chpid> ...
Meaning
Software error: The write operation is undefined for the selected opcode.
...I004 illegal operation - oper:<op> CHPID(s): <chpid> ...
Meaning
Software error: The transferred operation is undefined.
...I010 illegal opcode - opcode:<oc> CHPID(s): <chpid> ...
Meaning
Software error: The opcode is undefined.
...I011 illegal address - addr:<addr> CHPID(s): <chpid> ...
Meaning
Input error: The CASA address for the opcode is invalid.
...I089 SMAWLboot_G_DATA failed, .......
The system error message is appended to the message.
Meaning
Software error: The “read data from CASA” request has been aborted.
...I090 SMAWLboot_S_DATA failed, .......
The system error message is appended to the message.
Meaning
Software error: The “write data to CASA” request has been aborted.
...I091 mmap_x2 (<request>) failed
Meaning
Software error: The mmap_x2 request <request> has been aborted.
Page view 363
1 2 ... 359 360 361 362 363 364 365 366 367 368 369 ... 452 453

Comments to this Manuals