Web-Based Management (WBM)
4-14
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
4.7.3 System Factory Defaults
(restoring the defaults)
Figure 4-8 shows the Factory Defaults window.
Figure 4-8 System Factory Defaults Window
In this window, you can restore the factory default settings for the OSM/ESM.
Restore Factory Defaults
The settings made in the factory are restored. Even the protected settings (see
Section 2.4) are reset. There is no restart so that new data can be entered with the
WBM. The changes only take effect when a manual restart is triggered, see also
Section 4.7.2.
Restore Memory Defaults and Restart
The settings made in the factory are restored. This does not include the protected
defaults (see Section 2.4) that are not affected by this command. A restart is
triggered automatically.