Web-Based Management (WBM)
4-33
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
4.9.4 Agent Trap Configuration
Clicking the Trap Config menu opens the window shown in Figure 4-19.
Figure 4-19 Agent Trap Configuration Window
If an alarm occurs, the OSM/ESM can send traps (alarm messages) to up to 10
different (network management) stations at the same time, see Section 2.8. In this
menu, you enter the addresses of the stations to which the traps will be sent.
Follow the steps outlined below:
Set New Values
1. Enter the IP addresses of the stations to which the traps will be sent.
2. Click the check boxes beside the IP addresses to activate the sending of traps
to these stations.
Then click the Set New Values button.