Page view 30
Important OSM/ESM Functions
2-11
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
2.9 E-Mail Function
The OSM/ESM has an E-mail function with which an E-mail can be sent
automatically (for example to the network administrator) if an alarm occurs. If the
E-mail function is activated, the OSM/ESM sends an E-mail in the same situations
that lead to a trap being issued (see Section 2.8). The E-mail includes the
identification of the sending OSM/ESM and a description of the cause of the alarm
in plain language. For networks with only a few nodes, this allows simple
centralized network monitoring to be implemented on the basis of an E-mail
system. When an E-mail fault message arrives, the WBM can be started by the
browser based on the identification of the sender so that further diagnostic
information can be obtained.
To use the E-mail function, the following requirements must be met:
S The E-mail function is activated on the OSM/ESM and the E-mail address of
the recipient is configured.
S The E-mail function is activated for the particular event (event configuration,
activated for all events as default).
S There is an SMTP server in your network that can be reached by the
OSM/ESM.
S The IP address of the SMTP server is entered on the OSM/ESM.
The E-mail function can be activated by WBM or the command-line interface.
Note
Depending on the properties and configuration of the SMTP server, it may be
necessary to adapt the “From” box for the E-mails. Please check with the
administrator of the SMTP server. You can specify the “From” box using WBM,
CLI or by direct SNMP access.
Unless modified, the OSM/ESM uses the following address:
<device_type>@<IP_address>
For example, [email protected]