Siemens OSM User Manual Page 77

  • Download
  • Add to my manuals
  • Print
  • Page
    / 158
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 76
Web-Based Management (WBM)
4-16
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
Log Table File
Name of the log table file (maximum 32 characters) that is saved on the TFTP
server with the Save button.
If you do not enter a name for the configuration file and log table file, a file name
based on the IP address is used.
Firmware File
Name of the file on the TFTP server containing the new OSM/ESM firmware
(maximum 32 characters), if necessary with additional path information (depending
on the configuration of the TFTP server). Clicking the Load button starts the
download.
Note
If a configuration file of an RM was saved and then loaded on a normal
OSM/ESM, the OSM/ESM fault mask for the ring ports is set. Manual
reconfiguration may be necessary.
Page view 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 157 158

Comments to this Manuals

No comments