Page view 120
Upgrading/Downloading Software
6-5
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
The following dialog box then appears displaying the progress of the download.
Figure 6-4
Start the download by pressing the ”Set/Select” button again.
Downloading can take up to 10 minutes. After you have downloaded the firmware
successfully, the device is automatically started with the new firmware. Please note
the version of the new firmware on a label on the side labeling panel of the
OSM/ESM.
Note
During the download, do not interrupt the connection between the PC and
OSM/ESM and do not turn off the power supply to the OSM/ESM.
If the download is interrupted by a problem on a signal line, the device will start up
with the old firmware the next time it restarts. The firmware download must then
be repeated.
If the firmware could not be downloaded completely to the OSM due to a power
failure, the message ”Firmware in flash is faulty” appears after the device starts
up. This means that the firmware must be downloaded again.