Commissioning
7.2 Commissioning - Windows Embedded Standard
SIMATIC IPC427C
44 Operating Instructions, 10/2010, A5E02414743-03
7.2 Commissioning - Windows Embedded Standard
7.2.1 Basic commissioning - initial startup
Requirements
The device is connected to the 24 VDC power supply.
The equipotential bonding lines are wired.
The connecting cables are properly inserted.
Setting up the operating system
After initial power up, the Windows Embedded Standard operating system that is pre-
installed on the CompactFlash card, SSD, or hard disk is set up automatically on the
computer.
Proceed as follows:
1. Switch on the device using the On/Off switch. The device performs a power on self-test.
During the self-test, this message appears:
Press F2 go to Setup Utility or
Press ESC go to Boot Manager
2. Wait until this message is cleared, then follow the instructions on the screen.
NOTICE
The device may not be switched off at any time during the installation process.
Do not change the defaults in BIOS Setup, otherwise the operating system setup may
become corrupted.
3. Restart
After you have entered all the necessary information and the operating system is
configured,
you are prompted to restart the system. Respond to this prompt with Yes.
Note
Initial commissioning of Windows Embedded Standard 2009
System startup can take considerably longer than usual during initial commissioning of
Windows Embedded Standard 2009. Only a blue or black screen is displayed for several
minutes.