Siemens SIMATIC IPC427C Operations Instructions Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 182
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
Description
3.6 Design
SIMATIC IPC427C
24 Operating Instructions, 10/2010, A5E02414743-03
PROFINET status display (additional display for PROFINET variants)
PROFINET status display
LED Meaning LED Description
OFF
CP not available
CP disabled
No error, communication
established
Charging in progress
RED: Flashes slowly
Link status error
I/O controller: I/O device
cannot be addressed
I/O controller: Redundant IP
address
RED: Flashes rapidly Exception error: diagnostics via
Web or SNMP is no longer
possible
SF PROFINET Status display for
CP 1616 onboard
RED
Diagnostics information
available
No communication
established.
Virtual status displays
The two "virtual" CP 1616 LEDs are only visible in the SIMATIC software and can be read via SNMP.
RUN CP is active
STOP CP is in the stop state
PROFINET Virtual LEDs
Flashes The states "flashes slowly" or
"flashes rapidly" do not exist.
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 181 182