43
Commissioning
7
7.1 Note before commissioning
Factory state
The SIMATIC IPC427C is available in the following versions:
With Windows Embedded Standard 2009 or Windows Embedded Standard 7 operating
system (pre-installed on CompactFlash card, SSD, or hard disk)
With Windows XP Professional or Windows 7 Ultimate operating system (pre-installed on
SSD or hard disk)
Without operating system
Connections before commissioning
Before connecting the device to the power supply, a DVI or CRT monitor should be
connected in order for it to be correctly detected by the BIOS and the operating system
during startup.
CAUTION
Risk of damage to the device
If condensation has developed, wait at least 12 hours before commissioning the device.
NOTICE
Windows Embedded Standard 2009 / Windows Embedded Standard 7:
Read the EWF and FBWF information
Two configurable write filters (Enhanced Write Filter and File Based Write Filter) are
provided on systems running Windows Embedded Standard 2009 and Windows Embedded
Standard 7. Please be aware of this when activating and using the EWF/FBWF information,
otherwise you may experience data loss.
Note
Setting up CompactFlash cards on the employed device
If you want to use CompactFlash cards with the device, they need to be set up on the
device. CompactFlash cards set up on other devices will not boot due to the differing drive
parameters.