Page 1 - HVAC Products

Edition 3.0 Controller series B CE1U2354en 23. August 2007 Building TechnologiesHVAC Products Albatros2 Boiler controller User Manual RVS43..R

Page 2

10/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Type summary 23. August 2007 1.1 Type summary 1.1.1 Topology RemoteService Tool

Page 3 - Contents

100/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cascade 23. August 2007 2 x 1 cascade Line no. Operating line 2340 Auto source s

Page 4

101/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cascade 23. August 2007 1st changeover 2nd changeover 3rd changeover 4th

Page 5

102/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Solar 23. August 2007 6.14 Solar Charging controller (dT) Line no. Operating li

Page 6

103/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Solar 23. August 2007 DHW storage tank During solar charging, preference is given

Page 7

104/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Solar 23. August 2007 Frost protection for the collector Line no. Operating line

Page 8

105/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Solid fuel boiler 23. August 2007 Yield measurement Line no. Operating line 3880

Page 9 - 1 Summary

106/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Buffer storage tank 23. August 2007 TtBxTKxSDonSDoffOnOff2359Z138QX TKx Boiler te

Page 10 - 1.1 Type summary

107/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Buffer storage tank 23. August 2007 B4E1KTtTVLw4722 2355Z14 4722 Temp diff buffer/

Page 11 - (optionally with additional

108/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Buffer storage tank 23. August 2007 Off: The stratification protection function i

Page 12 - 2 Safety notes

109/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Buffer storage tank 23. August 2007 return temperature increase or return temperat

Page 13 - 3 Mounting and installation

11/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Type summary 23. August 2007 Operating options Wired Wireless BA BA CE1DBA2359Z66

Page 14 - On DIN rail

110/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products DHW storage tank 23. August 2007 01B4/B42 Cooling If the buffer storage tank was

Page 15 - 000020RVS63.243/109

111/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products DHW storage tank 23. August 2007 • Heating energy can be drawn off either by spac

Page 16 - 000020RVS63.283/109

112/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Instantaneous DHW heater 23. August 2007 Time program 4 / DHW For the electric imm

Page 17 - Use Slot Connector type

113/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Mixing valve control Line no. Operating line 5544

Page 18 - AVS82.491/109

114/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Heating Cooling Heating and cooling Q2HC/CCTB1Y1/Y

Page 19 - X50 of the basic unit using

115/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Separate DHW circuit Line no. Operating line 5736

Page 20

116/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Connections: Use Space Connector typeL1 Phase b

Page 21 - 3.4 Operator unit AVS37.294

117/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Burner control • 3-position control and modulating

Page 22 - 3.5 Operator unit AVS37.390

118/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 The 2x1 cascade is a special configuration of the b

Page 23 - 3.6 Room unit QAA55…

119/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 When using a charging pump, all heat exchangers can

Page 24 - 3.7 Room unit QAA75…

12/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Product liability 23. August 2007 2 Safety notes 2.1 Product liability • The pro

Page 25

120/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Collector pump Q5 When using a solar collector, a c

Page 26 - 3.8 Wireless components

121/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Heat gen shutoff valve Y4 If the buffer storage tank

Page 27

122/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 St tank transfer pump Q11 If the temperature level o

Page 28

123/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Cascade return sensor B70 Swimming pool sensor B13 C

Page 29 - Testmode

124/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Error / alarm message Input H1 generates a controlle

Page 30 - Outside sensor

125/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Dewpoint monitor The dewpoint monitor detects the fo

Page 31

126/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 The function “Min flow temp setpoint” on operating l

Page 32

127/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 • Example of relative room humidity 10V If the m

Page 33 - 3.9 Power supply AVS16.290

128/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Input H1 and H3 for RVS63.. The following settings

Page 34 - 0.5...3.0

129/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Minimum flow temperature setpoint TVHw The adjuste

Page 35 - 4 Commissioning

13/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Regulations 23. August 2007 3 Mounting and installation 3.1 Regulations Electrica

Page 36 - 5 Handling

130/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 The pressure value at 0.5 V is fixed at 0 bar. The p

Page 37 - Xxxxxxxxxxxxxxxxxxxxxxxxxxx

131/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 The voltage signal present at input H… is converted

Page 38

132/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Excess heat discharge Active dissipation of excessiv

Page 39 - 30:Flow sensor 1

133/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Cooling circuit 1 For this application, the respecti

Page 40 - Reset ? yes

134/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Connections: QX21 QX22 QX23 BX21 BX22 H2 Page

Page 41 - 5.1.2 Programming

135/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 BX extension module Can be configured for freely se

Page 42 - 5.1.3 User levels

136/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 10V output UX Line no. Operating line 6070 Functio

Page 43 - OEMEnduser

137/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Building and room model Line no. Operating line 61

Page 44 - 5.1.4 Overview of settings

138/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Sensor state Line no. Operating line 6200 Save sens

Page 45

139/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Solar Oil / gas boiler One collector field with

Page 46

14/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic units RVS… 23. August 2007 2359Z10xMounting method Screwed On DIN rail 2359

Page 47

140/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Configuration 23. August 2007 Buffer storage tank DHW storage tank 0 No bu

Page 48

141/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products LPB 23. August 2007 Displays on the operator unit: Check-No. heat source 1 101

Page 49

142/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products LPB 23. August 2007 6627 Refrigeration demand Locally¦ Centrally 6631 Ext sour

Page 50 - Off ¦ On

143/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Faults 23. August 2007 Economy mode can be selected from menu ”Special operation

Page 51

144/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Maintenance/special mode 23. August 2007 The difference of setpoint and actual tem

Page 52

145/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Maintenance/special mode 23. August 2007 For safety reasons, maximum limitation of

Page 53

146/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Input / output test 23. August 2007 Auxiliary functions Alarm output K10 Off T

Page 54

147/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products State 23. August 2007 6.24 State The current operating state of the plant is visu

Page 55

148/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products State 23. August 2007 Frost protection active 24 Cooling limit OT active Coolin

Page 56

149/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products State 23. August 2007 Charging buffer storage tank Charging buffer storage tank

Page 57

15/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic units RVS… 23. August 2007 3.2.1 Connection terminals of RVS43.143 2354Z0

Page 58

150/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Diagnostics, heat generation 23. August 2007 Charged, forced charg required temp

Page 59

151/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products List of displays 23. August 2007 6.27 List of displays Priorities are assigned to

Page 60

152/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products List of displays 23. August 2007 320 DHW charging temperature sensor error 6 321

Page 61

153/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic diagrams 23. August 2007 7 Plant diagrams The various applications are show

Page 62

154/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic diagrams 23. August 2007 2358A33CY1/Y2B1Q2RG1B9H/CY21C 7.1.2 Basic diagra

Page 63

155/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic diagrams 23. August 2007 7.1.3 Basic diagram RVS63.283 2358A03B3Q3Y1B1Q2R

Page 64

156/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Versions of heat sources 23. August 2007 7.2 Versions of heat sources The heat

Page 65 - 5.2 AVS37.390

157/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extra functions in general 23. August 2007 7.3 Extra functions in general The ex

Page 66

158/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extra functions in general 23. August 2007 Solar storage tank and swimming pool ch

Page 67 - 3.1.2 Programming

159/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extra functions in general 23. August 2007 Boiler Boiler pump Bypass pump 2358A0

Page 68 - 5.2.2 User levels

16/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic units RVS… 23. August 2007 3.2.3 Connection terminals of RVS63.283 2354Z0

Page 69 - 5.2.3 Overview of settings

160/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extra functions in general 23. August 2007 DHW storage tank (DHW) DHW circulating

Page 70 - 5.3 QAA55

161/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extra functions in general 23. August 2007 Return diversion Partial tank charging

Page 71 - − Press OK

162/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extra functions in general 23. August 2007 Heat converter System pump Q14 Q14235

Page 72 - 5.3.2 Programming

163/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Additional funct. with mix. valve group or extension module AVS75.390 23. August 2

Page 73 - 6 The settings in detail

164/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Additional funct. with mix. valve group or extension module AVS75.390 23. August 2

Page 74 - 40 Used as

165/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Additional funct. with mix. valve group or extension module AVS75.390 23. August 2

Page 75 - All heating circuits

166/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Additional funct. with mix. valve group or extension module AVS75.390 23. August 2

Page 76 - 6.4 Time programs

167/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Additional funct. with mix. valve group or extension module AVS75.390 23. August 2

Page 77 - 6.6 Heating circuits

168/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic units RVS… 23. August 2007 8 Technical data 8.1 Basic units RVS… Rated vol

Page 78

169/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extension module AVS75.390 23. August 2007 BSB Max. cable length Basic unit –

Page 79 - HC1 HC2 HCP

17/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic units RVS… 23. August 2007 Terminal markings Use Slot Connector typeL Liv

Page 80 - Setting line e.g

170/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Operator unit and room units AVS37... / QAA7x… / QAA55.. 23. August 2007 Relay out

Page 81 - 750 1050 1350 Room influence

171/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Power supply AVS16.290 23. August 2007 CE conformity to EMC directive - Immunity

Page 82 - 770 1070 1370 Boost heating

172/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Wireless outside sensor AVS13.399 23. August 2007 Degree of protection of housing

Page 83 - 780 1080 1380 Quick setback

173/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Radio repeater AVS14.390 23. August 2007 8.7 Radio repeater AVS14.390 Nominal vol

Page 84 - Xein Xaus

174/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Sensor characteristics 23. August 2007 8.8 Sensor characteristics 8.8.1 NTC 1 k

Page 85 - TRwA2TRwA1

175/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Sensor characteristics 23. August 2007 8.8.2 NTC 10 k T [°C] R[Ohm] T [°C] R[

Page 86

176/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 Index 2 2 x 1 cascade ...

Page 87

177/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 heating curve displacement ... 78, 79

Page 88 - 6.7 Cooling circuit

178/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 shifting priority ...

Page 89

179/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 9 Revision history All changes made to the document since the las

Page 90 - TVKw_unb

18/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic units RVS… 23. August 2007 Use Slot Connector typeBSB Service tool OCI70

Page 91 - 932 Room temp limitation

180/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 Siemens Schweiz AG Siemens Switzerland Ltd Building Technologi

Page 92 - Control ¦ Open

19/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extension module AVS75.390 23. August 2007 3.3 Extension module AVS75.390 For pla

Page 93 - 950 Flow temp diff dewpoint

2/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007

Page 94

20/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Extension module AVS75.390 23. August 2007 Terminal markings Use Slot Connector

Page 95 - 6.8 DHW

21/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Operator unit AVS37.294 23. August 2007 3.4 Operator unit AVS37.294 Mounting met

Page 96 - 6.9 H.. pumps

22/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Operator unit AVS37.390 23. August 2007 3.5 Operator unit AVS37.390 Connections T

Page 97 - 6.10 Swimming pool

23/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Room unit QAA55… 23. August 2007 3.6 Room unit QAA55… Engineering @ The room uni

Page 98 - 6.12 Boiler

24/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Room unit QAA75… 23. August 2007 3.7 Room unit QAA75… Engineering @ The r

Page 99 - 2331 Output of basic stage

25/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Room unit QAA75… 23. August 2007 Dimensions and drilling plan 2359Z504,25660566010

Page 100 - 6.13 Cascade

26/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Wireless components 23. August 2007 3.8 Wireless components The wireless compone

Page 101 - changeover

27/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Wireless components 23. August 2007 3.8.2 Room unit QAA78.610 Engineering

Page 102 - 6.14 Solar

28/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Wireless components 23. August 2007 2359Z61 Connection / power supply The room un

Page 103 - 103/180

29/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Wireless components 23. August 2007 Example of a display during the test: The dig

Page 104 - 3871 Pump speed max

3/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 Contents 1 Summary ...

Page 105 - 6.15 Solid fuel boiler

30/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Wireless components 23. August 2007 2359Z533.8.3 Wireless outside sensor AVS13.399

Page 106 - 2359Z138

31/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Wireless components 23. August 2007 Radio connection Make the radio connection in t

Page 107 - Line no. Operating line

32/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Wireless components 23. August 2007 3.8.4 Radio repeater AVS14.390 • To establis

Page 108

33/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Power supply AVS16.290 23. August 2007 3.8.5 Checking the wireless components To

Page 109

34/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Power supply AVS16.290 23. August 2007 Mains supply to

Page 110 - 6.17 DHW storage tank

35/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Basic units 23. August 2007 4 Commissioning To commission the units, the following

Page 111 - 111/180

36/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 5 Handling 5.1 QAA75.. / QAA78… / AVS37

Page 112 - 112/180

37/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Display options Heating to Comfort setp

Page 113 - 6.19 Configuration

38/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 • Protective functions active • Automa

Page 114 - 5730 DHW sensor B3

39/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Presence button If you do not use the r

Page 115 - 5770 Type of heat source

4/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 3.8.2 Room unit QAA78.610 ...

Page 116 - Use Space Connector type

40/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 A list of possible displays is given on

Page 117 - 117/180

41/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 5.1.2 Programming Setting principle Set

Page 118

42/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 5 04 8 12 16 20 24AUTO2359Z140Time

Page 119 - Diverting valve, cooling Y21

43/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Text304 8 12 16 20 24AUTO2359Z140O

Page 120 - 120/180

44/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 5.1.4 Overview of settings The table sh

Page 121 - 121/180

45/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 122 - Sensor input BX1, 2, 3, 4

46/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 123 - Input H1 for RVS43

47/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 124 - 124/180

48/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 125 - 125/180

49/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 126 - 1/U1 and F2/U2)

5/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 5.2.2 User levels...

Page 127 - 2=10VU1=0V

50/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 128 - Input H1 and H3 for RVS63

51/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 129 - 129/180

52/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 130

53/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 131 - H1 Voltage at H

54/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 132 - Function mixing group 1

55/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 133

56/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 134

57/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 135 - RVS63.. only

58/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 136

59/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 137 - 01234-3-4-5-6 -1

6/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 Flow temperature setpoint limits ...

Page 138

60/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 139 - Check-No. heat source 2

61/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 140 - 140/180

62/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 141 - 6.20 LPB

63/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 142 - 6627 Refrigeration demand

64/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA75.. / QAA78… / AVS37.. 23. August 2007 Operating line User level Function Defau

Page 143 - 6.21 Faults

65/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products AVS37.390 23. August 2007 5.2 AVS37.390 5.2.1 Operation Operating elements 2354Z1

Page 144

66/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products AVS37.390 23. August 2007 Adjusting the room temperature setpoint Press the + / -

Page 145 - 7140 Manual control

67/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products AVS37.390 23. August 2007 3.1.2 Programming Setting principle Settings that cannot

Page 146 - 6.23 Input / output test

68/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products AVS37.390 23. August 2007 4 + 1235 4Z13 The display shows the minutes flashing. P

Page 147 - 6.24 State

69/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products AVS37.390 23. August 2007 5.2.3 Overview of settings The table shows all available

Page 148 - State of boiler

7/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 6.17 DHW storage tank ...

Page 149 - State buffer storage tank

70/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA55... 23. August 2007 5.3 QAA55... 5.3.1 Operation Operating elements 2358Z3

Page 150 - 6.26 Diagnostics, consumers

71/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA55... 23. August 2007 Continuous operation or Continuous operation mainta

Page 151 - 6.27 List of displays

72/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products QAA55... 23. August 2007 5.3.2 Programming A long press on the presence button ena

Page 152 - 6.27.2 Maintenance code

73/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Time of day and date 23. August 2007 6 The settings in detail 6.1 Time of day and

Page 153 - 7.1 Basic diagrams

74/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Operator unit 23. August 2007 Line no. Operating line 40 Used as Room unit 1 Room

Page 154 - Heating/cooling via

75/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Operator unit 23. August 2007 Heating circuit assignment Line no. Operating line 4

Page 155 - 155/180

76/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Radio 23. August 2007 6.3 Radio Binding Line no. Operating line 120 Binding 121 T

Page 156 - 156/180

77/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Holidays 23. August 2007 Switching points Line no. Operating line HC1 HC2 3/HCP

Page 157 - 157/180

78/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 Setpoints Line no. Operating line HC1 HC2 HCP

Page 158 - 158/180

79/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 Parallel displacement of the heating curve is us

Page 159 - Flue gas temperature sensor

8/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products 23. August 2007 6.27 List of displays ...

Page 160 - 160/180

80/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 • The function is not active in operating mode ”C

Page 161 - Partial tank charging

81/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 Using this limitation, a temperature range for the

Page 162 - H.. Pump

82/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 The flow temperature is controlled depending on th

Page 163 - 2-pipe 4-pipe

83/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 TRw Room temperature setpoint TRx Actual value

Page 164 - 164/180

84/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 Optimum start / stop control Line no. Operating

Page 165 - Return controller

85/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 2358Z06-15-5TRTRKTAgemTRwA2TRwA1TRR TRwA1 Reduced

Page 166 - Release modulating burner

86/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 Floor curing function Line no. Operating line HC

Page 167 - 167/180

87/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Heating circuits 23. August 2007 The flow temperature setpoint for the "Manual

Page 168 - 8.1 Basic units RVS…

88/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cooling circuit 23. August 2007 6.7 Cooling circuit For the operation of a cooling

Page 169 - 169/180

89/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cooling circuit 23. August 2007 Cooling curve Line no. Operating line 908 Flow se

Page 170 - temp. -20…65 °C

9/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Type summary 23. August 2007 1 Summary The present User Manual describes the produc

Page 171 - (±10 %)

90/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cooling circuit 23. August 2007 Summer compensation starts to take effect at the ou

Page 172 - class 1K3, temp. -20…65 °C

91/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cooling circuit 23. August 2007 Room influence Line no. Operating line 928 Room in

Page 173

92/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cooling circuit 23. August 2007 The cooling circuit pump is activated again as soon

Page 174 - 8.8 Sensor characteristics

93/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cooling circuit 23. August 2007 Controls The valve is used for control in heating

Page 175 - 175/180

94/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Cooling circuit 23. August 2007 TATVKwTTPTBZ 950 TVKw Flow temperature setpoint,

Page 176 - 176/180

95/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products DHW 23. August 2007 6.8 DHW Setpoints Line no. Operating line 1610 Nominal setpoi

Page 177 - 177/180

96/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products H.. pumps 23. August 2007 1642 Legionella funct weekday Monday…Sunday 1644 Legion

Page 178 - 178/180

97/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Swimming pool 23. August 2007 Excess heat draw can be triggered by the following f

Page 179 - 9 Revision history

98/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Primary controller / system pump 23. August 2007 If the swimming pool is enabled vi

Page 180

99/180 Siemens Schweiz AG User Manual CE1U2354en HVAC Products Boiler 23. August 2007 In normal operation, minimum limitation of the boiler temper

Comments to this Manuals

No comments