Example "Motion"
5.8 Start diagnostics view
STEP 7 Basic V10.5
Getting Started, 12/2009, A5E02651459-01
195
9. Display the motion status.
The current position of the motor axis is shown in the "Current position" field. When the
target position of 500 mm relative to the start position is reached, the axis is set to stop.
Result
You have used the diagnostics function to check the proper functioning of the motor axis.