Siemens TC65 Specifications Page 95

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 94
TC65 Hardware Interface Description
Confidential / Released
s
TC65_HD_V02.000 Page 95 of 120 08.06.2006
5.6 Power Supply Ratings
Table 27: Power supply ratings
Parameter Description Conditions Min Typ Max Unit
Supply voltage Directly measured at reference point
TP BATT+ and TP GND, see chapter
3.2.2
Voltage must stay within the min/max
values, including voltage drop, ripple,
spikes.
3.2 3.8 4.5 V
Voltage drop during
transmit burst
Normal condition, power control level
for P
out max
400 mV
BATT+
Voltage ripple Normal condition, power control level
for P
out max
@ f<200kHz
@ f>200kHz
50
2
mV
mV
I
VDDLP
RTC Backup @ BATT+ = 0V 25 µA OFF State
supply current
POWER DOWN mode
7
50 100 µA
SLEEP mode @ DRX = 9 3.7
9
mA
SLEEP mode @ DRX = 5
4.6
9
mA
SLEEP mode @ DRX = 2
7.0
9
mA
I
BATT+
Average standby
supply current
8
IDLE mode @ DRX = 2 28
10
mA
7
Measured after module INIT (switch ON the module and following switch OFF); applied voltage on BATT+ (w/o
INIT) show increased POWER DOWN supply current.
8
Additional conditions:
- SLEEP and IDLE mode measurements started 5 minutes after switching ON the module or after mode
transition
- Averaging times: SLEEP mode - 3 minutes; IDLE mode - 1.5 minutes
- Communication tester settings: no neighbor cells, no cell reselection
- USB interface disabled
9
Stated value applies to operation without autobauding (AT+IPR0).
10
Stated value applies to operation without autobauding (AT+IPR0). If autobauding is enabled (AT+IPR=0)
average current consumption in IDLE mode is up to 43mA.
Page view 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 119 120

Comments to this Manuals

No comments