3.3.4.4 Undervoltage Shutdown if no Battery NTC is Present
The undervoltage protection is also effective in applications, where no NTC connects to the
BATT_TEMP terminal. Thus, you can take advantage of this feature even though the
application handles the charging process or TC65 is fed by a fixed supply voltage. All you
need to do is executing the write command AT^SBC=<current> which automatically enables
the presentation of URCs. You do not need to specify <current>.
Whenever the supply voltage falls below the value of 3.2V the URC
^SBC: Undervoltage
appears several times before the module switches off.
This type of URC does not need to be activated by the user. It will be output automatically
when fault conditions occur.
3.3.4.5 Overvoltage Shutdown
The overvoltage shutdown threshold is 100mV above the maximum supply voltage V
BATT+
specified in
Table 27.
When the supply voltage approaches the overvoltage shutdown threshold the module will
send the URC
^SBC: Overvoltage warning.
This alert is sent once.
When the overvoltage shutdown threshold is exceeded the module will send the URC
^SBC: Overvoltage shutdown,
before it shuts down cleanly.
This type of URC does not need to be activated by the user. It will be output automatically
when fault conditions occur.
Keep in mind that several TC65 components are directly linked to BATT+ and, therefore, the
supply voltage remains applied at major parts of TC65, even if the module is switched off.
Especially the power amplifier is very sensitive to high voltage and might even be destroyed.