User Guide
Chapter 5
Setup and Configuration
Deleting a Remote Host 147
Parameter Description
IP Address Synopsis: ###.###.###.### where ### ranges from 0 to 255
Default:
The IP address of the remote host.
IP Port Synopsis: 1 to 65535 or { Unknown }
Default: 50000
The IP port that remote host listens to. If this is zero (Unknown), the unit only receives
from the remote host but does not transmit to it.
Port(s) Synopsis: Any combination of numbers valid for this parameter
Default: All
The local serial ports that the remote host is allowed to communicate with.
4. Click Apply.
Section 5.4.16.3
Deleting a Remote Host
To delete a remote host used by the Raw socket protocol, do the following:
1. Navigate to Serial Protocols » Configure Protocols » Configure Raw Socket » Configure Remote
Hosts. The Remote table appears.
Figure 104: Remote Table
2. Select the remote host from the table. The Remote form appears.