Siemens RUGGEDCOM RSG2200 User's Guide Page 150

  • Download
  • Add to my manuals
  • Print
  • Page
    / 170
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 149
Chapter 5
Setup and Configuration
RUGGEDCOM ROS
User Guide
138 Configuring the DNP Protocol
6
5
1
2
3
4
Figure 93: MicroLok Form
1. Transport Options 2. IP Port Box 3. Link Stats Options 4. DSCP Box 5. Apply Button 6. Reload Button
3. Configure the following parameter(s) as required:
Parameter Description
Transport Synopsis: { TCP, UDP, Disabled }
Default: UDP
The network transport used to transport protocol data over an IP network.
IP Port Synopsis: 1024 to 65535
Default: 60000
A local port number on which the MicroLok protocol listens for UDP datagrams or TCP
connections.
Link Stats Synopsis: { Disabled, Enabled }
Default: Enabled
Enables link statistics collection for this protocol.
DSCP Synopsis: 0 to 63
Default: 0
To set the DS byte in the IP header. DS byte setting is supported in the egress direction
only.
4. Click Apply.
Section 5.4.12
Configuring the DNP Protocol
To configure the DNP protocol for a serial port, do the following:
1. Make sure the serial port is configured to use the DNP protocol. For more information, refer to Section 5.4.5,
“Configuring a Serial Port”.
2. Navigate to Serial Protocols » Configure Protocols » Configure DNP Protocol » Configure DNP. The
DNP form appears.
Page view 149
1 2 ... 145 146 147 148 149 150 151 152 153 154 155 ... 169 170

Comments to this Manuals

No comments