Configuration Using Web Based Management and the Command Line Interface
Operating Instructions SCALANCE W 744-1PRO
48 C79000-G8976-C185-03
5.2.3 Services Menu Command
Configuration
Here, you select the services with which access to the SCALANCE W744 will be
possible. If, for example, the SNMP Enabled check box is not selected, neither wri-
te nor read access is possible using the SNMP protocol (v1,v2c,v3). If the SNMP
protocol is not permitted, it is not possible to send SNMP traps.
To improve security, you should only enable the services that you actually use.
Notice
Over SNMP, it is possible to disable all services and to allow read access only over
SNMP. Following this, no further configuration of the SCALANCE W744 is possi-
ble.
Notes on WEB Enabled in the WEB Interface
The check box for the WEB Enabled entry is selected and inactive because con-
figuration with Web Based Management is no longer possible without the option of
access with HTTP.
If you want to deactivate the option of configuration with Web Based Management,
you can do this in the Security Wizard over Telnet and SNMP. Settings made using
the Security Wizard only take effect after a restart on the SCALANCE W744.
Syntax of the Command Line Interface
CLI\SYSTEM\SERVICES>
Command Description Comment
telnet [E|D]
Enable / disable configuration of the
SCALANCE W744 over Telnet.
Only WEB and SNMP
ttimeout [E|D]
Enables / disables the time restric-
tion for a Telnet session.
ttimeout [time in s]
Specifies the time after which a Tel-
net section is closed if there is no
further input.
snmp [E|D]
Enable / disable SNMP.
mail [E|D]
Enable / disable E-mail.