3. Decide how the device will obtain its IP address:
Dynamically from a DHCP server:
Select the Obtain IP address from DHCP server option button.
Manual assignment by the user:
Select the Assign IP parameters option button.
4. Make the following entries if you have decided to assign the IP address manu-
ally:
Enter the IP address for the device in the IP Address box. In each part of
the address separated by the periods, you can enter a number between 0
and 255; the program does not accept any other numbers.
Enter the subnet mask in the Subnet Mask box.
If necessary, select the Use router check box and enter the IP address of
the router in the text box. Router information is necessary if the computer
on which you are creating the configuration is not in the same subnet as
the SCALANCE W744.
Downloading to the Module
Follow the steps below to transfer the configuration data to the device:
1. Select the module to which you will download the configuration data in the left-
hand pane of the program window. As long as an interface is selected and the
input dialog for the configuration data is displayed, no download is possible.
2. Start the download with the steps outlined below:
Select the Module > Download menu command.
Click the second icon from the left in the toolbar (S7 modules with yellow
arrow).