Configuration with the Primary Setup Tool
Operating Instructions SCALANCE W 744-1PRO
C79000-G8976-C185-03
37
Browsing the Network
Before you assign IP addresses with the PST, you must first locate the configur-
able devices in the network. Start this search with the steps outlined below:
Select the Network > Browse menu command.
Click on the magnifier icon in the toolbar below the menu bar.
While the Primary Setup Tool browses the network, the Browse Network dialog is
displayed with a progress bar. On completion of the search, the Primary Setup
Tool displays a list with all the devices it has found in the left-hand pane.
Configuring a Module
If you click an entry in the list, the Primary Setup Tool displays information on the
selected device in the right-hand pane.
Follow the steps below to configure a device:
1. Click on the plus symbol in front of the device symbol or double-click on the
device symbol to display all interfaces of the device.
2. Click on the interface you want to configure. The Primary Setup Tool displays
the input dialog for the configuration data in the right-hand pane of the pro-
gram window. Depending on the selected settings, some text boxes or check
boxes may be disabled. The MAC address box is always disabled because
this address is a property of the device that cannot be modified. The Client ID
parameter and DNS is also not supported by the SCALANCE W744.