Issue 01/06 Parameter Description
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
205
P2051[8] CI: PZD to CB Min: 0:0
CStat: CT Datatype: U32 Unit: - Def: 52:0
P-Group: COMM Active: Immediately QuickComm.: No Max: 4000:0
Selects signals (process data PZD) to be transmitted via CB on COM link
.
.
.
[0]
P2051
[1]
[2]
[3]
[7]
r0021
r0052
r0052
r0053
r0053
PZD1
ZSW1
PZD2
HIW
PZD3PZD4
ZSW2
P2041[0]
PKW
PZD
ZSW
HIW
PZD mapping from parameter P2051
CB on COM link
USS telegram
Parameter ID value
Process data
CB-Frame
PKWPZD
CB-Frame
Process data
Parameter
Status word
Main actual value
Index:
P2051[0] : Transmitted word 0
P2051[1] : Transmitted word 1
P2051[2] : Transmitted word 2
P2051[3] : Transmitted word 3
P2051[4] : Transmitted word 4
P2051[5] : Transmitted word 5
P2051[6] : Transmitted word 6
P2051[7] : Transmitted word 7
Common Settings:
- Status word 1 = 52 CO/BO: Act. status word 1 (see r0052)
- Actual value 1 = 21 inverter output frequency (see r0021)
- Other BICO settings are possible
r2053[5] CB identification Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMM Max: -
Displays identification data of the communication board (CB). The different CB types (r2053[0]) are given in
the Enum declaration.
Possible Settings:
0 No CB option board
1 PROFIBUS DP
2 DeviceNet
256 not defined
Index:
r2053[0] : CB type (PROFIBUS = 1)
r2053[1] : Firmware version
r2053[2] : Firmware version detail
r2053[3] : Firmware date (year)
r2053[4] : Firmware date (day/month)
r2054[7] CB diagnosis Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMM Max: -
Displays diagnostic information of communication board (CB).
Index:
r2054[0] : CB diagnosis 0
r2054[1] : CB diagnosis 1
r2054[2] : CB diagnosis 2
r2054[3] : CB diagnosis 3
r2054[4] : CB diagnosis 4
r2054[5] : CB diagnosis 5
r2054[6] : CB diagnosis 6
Details:
See relevant communications board manual.